Road Reader Model 3430/3440 Moisture Density Gauge
The Troxler nuclear moisture density gauges are used by many contractors, engineers, and highway departments for compaction control of soil aggregate, concrete, and full depth asphalt. The gauges meet or exceed the ASTM standards D6938, D2950, and C1040. The operator selects the density measurement mode, backscatter, or direct transmission based on the material type and the thickness of the layer being measured.
These updated gauges offer new standard features and many optional new features. The owner can customize the gauge to meet their testing needs.
The Model 3430 is the simplest and most economical gauge offered by Troxler. This gauge offers many features, including:
- Improved operation and reliability with updated electronics
- Fast recharge with NiMH batteries
- Easier to read in all lighting situations with an enlarged backlit display screen – 8mm characters
Optional features for the Model 3430 include:
- Remote start keypad near the handle
- Alkaline batteries for backup use
- External beeper
- Software, keypad, and manual in Spanish and French
- Data storage
- USB port
The Model 3440 is for users who want user-friendly features. Along with the standard features provided in the Model 3430, the Model 3440 provides additional features including:
- Automatic depth function
- USB port for data transfer
- Data storage (1000 readings)
- Alkaline battery backup
Optional features offered for the Model 3440 include:
- GPS location
- Remote start keypad near the handle
- Backlit keypad
- External beeper
- Software, keypad, and manual in Spanish and French
Both models offer:
- Density measurement capability in backscatter or direct transmission mode
- Moisture measurement in backscatter mode to allow quick, non-destructive testing of soil, asphalt and concrete materials
- Direct readout of test results (wet density, dry density, moisture, % moisture, % voids, and % compaction)
- Multiple count time options (15 seconds, 1 minute, 4 minutes)
- User-friendly menus and keypads
- Options of 12”/2”, 12”/1” and 8”/2” depth measurement capability
- 18 month warranty
For information on the legacy 3430 and 3440 Gauges, refer to the Documents TAB.
Specifications
Measurement Specifications
Direct Transmission (150 mm) | |||
.25 min | 1 min | 4 min | |
Precision kg/m3 (pcf) | ±6.8 (±0.42) | ±3.4 (±0.21) | ±1.7 (±0.11) |
Composition error (kg/m3) (pcf) | ±20.0 (±1.25) | ±20.0 (±1.25) | ±20.0 (±1.25) |
Surface error (kg/m3) (100% Void) |
–17.0 (-1.25) | –17.0 (-1.25) | –17.0 (-1.25) |
Backscatter (98%, 100 mm) | |||
Precision (kg/m3) (pcf) | ±16.0 (±1.0) | ±8.00 (±0.50) | ±4.00 (±0.25) |
Composition error (kg/m3) (pcf) | ±40.0 (±2.50) | ±40.0 (±2.50) | ±40.0 (±2.50) |
Surface error (kg/m3) (100% Void) (pcf) |
-75.0 (-4.68) | -75.0 (-4.68) | -75.0 (-4.68) |
Surface error (kg/m3) (100% Void) (pcf) |
-75.0 (-4.68) | -75.0 (-4.68) | -75.0 (-4.68) |
Moisture at 240 kg/m3 | |||
Precision (kg/m3) (pcf) | ±10.3 (±0.64) | ±5.1 (±0.32) | ±2.6 (±0.16) |
Surface error (kg/m3) (1.25 mm, 100% void, kg/m3) (pcf) |
-18.0 (-1.12) | -18.0 (-1.12) | -18.0 (-1.12) |
Mechanical Specifications
Gauge Size (including handles) | 12” – 23.5”x9”x14.5” (59cm x 22.9cm x 36cm) 8” – 19.5” height (49.5cm) |
Shipping Case Size | 29.4” x 13.9” x 16.5” |
(75cm x 35cm x 42cm) | |
Shipping Weight | 83lbs (37.6kg) |
Weight | 31lbs (14.1kg) |
Operating Temperature | 32º to 122º F (0º to 50º C) |
Surface | 350°F (175°C) for 15 minutes |
Storage Temperature | 0º to 140º F (-18º to +60º C) |
Radiological Specifications
Gamma Source | 0.30 GBq (8mCi) ± 10% Cs-137 |
Neutron Source | 1.48 GBq (40mCi) ± 10% Am-241:Be |
Source Housing | Stainless steel, encapsulated |
Surface Dose Rate | (5cm) 19 mrem/hr maximum, neutron and gamma |
Shipping Case | DOT 7A, Type A, Yellow II label, TI=0.3 |
Electrical Specifications
Main Power Source | 5C NiMH (Rechargeable Pack) |
Backup Power Source | 5 AA Alkaline Batteries – 3440 Optional – 3430 |
Stored Power | 4 Ampere hours |
Battery Recharge Time | 3 hours maximum, auto cutoff |
Charge Source | 110/220 VAC, 50 or 60 Hz or 12-14 VDC |
Current Consumption Average | 35 mA |
Time Before Auto Shutdown | 5 hours of inactivity |
Readout | 4 x 20 Alphanumeric |
Keypad | 30 key sealed membrane – 3440 10 key sealed membrane – 3430 |
Options
Model 3430 Options:
- Remote start keypad near the handle
- External Beeper
- Data Storage (100 readings)
- USB port for data transfer
- Alkaline battery backup feature
- Spanish and French language options
Model 3440 Options:
- Remote start keypad on the handle
- External beeper
- Backlit keypad for low light conditions
- GPS locations for measurements